Method of using multi-enzyme cleaning solution:
1. To inspect the contamination degree of the articles to be cleaned. Dilute the multi-enzyme cleaning solution according to the degree of contamination. The general dilution degree is about 100-200 times.
2. The products that need to be cleaned are immersed in diluted multi-enzyme cleaning solution. The immersion time is about 2-10 minutes. If the immersion time is slightly shorter, the multi-enzyme cleaning solution with slightly higher concentration can be diluted. However, it should be noted that the concentration of multi-enzyme cleaning solution should not be too high, otherwise the cleaning effect will be very poor.
3. Clean the soaked instruments with clean water and then disinfect them.
Notes for multi-enzyme cleaning solution:
1. The products cleaned by multi-enzyme cleaning solution do not need traditional manual cleaning operation.
2. If the cleaning machine is used for cleaning, the multi-enzyme cleaning solution can be used as one of the cleaning solutions.
3. The use environment of multi-enzyme cleaning solution must be between 5.5 and 9.0 PH value, but in the environment between 6.5 and 7.5 PH value, the use effect ** is good.
4. When using multi-enzyme cleaning solution for cleaning, the water temperature ** is better between 10 and 60 degrees Celsius.
5. Multi-enzyme cleaning solution can not directly contact the skin and mucosa. If it touches the skin and mucosa carelessly, it must be cleaned with a large amount of water for more than 15 minutes.
6. The multi-enzyme cleaning solution can only be diluted by adding water before use. Do not touch water before use, otherwise it will lead to the failure of multi-enzyme cleaning solution. ** It is better to dilute the existing solution, and the bottle cap must be tightened after the introduction of use, otherwise the effect of multi-enzyme cleaning solution may be affected.
7. When using multi-enzyme cleaning solution for manual cleaning of medical gastroscope, we should pay attention to the following steps: (1) wiping and cleaning with flowing water; (2) soaking with fast multi-enzyme cleaning solution; (3) disinfecting with glutaraldehyde; (4) repeatedly cleaning with flowing water.
The above content is the introduction of the usage method and precautions of multi-enzyme cleaning solution. If you have other related questions, please contact us.